LIANCHUANG GAOKE AUTOMATION
OEM equipment manufacturers can customize the frequency converters that you prefer and install them on your products.
3PH 380V±15% 1.5kw-200kw
Keywords:
Solar Pump model
Water Pump and Fans control model
Products Detail
|
Power |
Motor |
Rated Output Current (A) |
|
|
kW |
HP |
||
|
3PH 380V±15% |
|||
|
1.5kW |
1.5 |
2 |
4.4 |
|
2.2kW |
2.2 |
3 |
5.8 |
|
4.0kW |
4.0 |
5 |
10 |
|
5.5kW |
5.5 |
7.5 |
13 |
|
7.5kW |
7.5 |
10 |
17 |
|
11kW |
11 |
15 |
25 |
|
15kW |
15 |
20 |
32 |
|
18.5kW |
18.5 |
25 |
37 |
|
22kW |
22 |
30 |
45 |
|
30kW |
30 |
40 |
60 |
|
37kW |
37 |
50 |
75 |
|
45kW |
45 |
60 |
90 |
|
55kW |
55 |
75 |
110 |
|
75kw |
75 |
100 |
150 |
|
90kw |
90 |
120 |
176 |
|
110kw |
110 |
150 |
210 |
|
132kw |
132 |
180 |
255 |
|
160kw |
160 |
215 |
305 |
|
185kw |
185 |
250 |
340 |
|
200kw |
200 |
270 |
377 |
2.2 Technical Specifications
|
Item |
Technical Index |
Specification |
|
Input |
Input voltage |
Three-phase AC380V; 50/60Hz Single-phase AC 220V; 50/60Hz |
|
Voltage tolerance Variation Range |
Three-phase AC360V to 450V Single-phase AC190V to 250V |
|
|
Output |
Output voltage |
0–460V 0 to 260V |
|
Output frequency |
Vector Control: 0 to 500 Hz V/F Control: 0 to 500 Hz |
|
|
Output |
Overload capacity |
G model: 150%/60s, 200%/4s P model: 120%/60s, 150%/1s |
|
Control mode |
V/F control, Sensorless Vector Control (SVC) |
|
|
Control characteristics |
Frequency setting resolution |
Digital setting: 0.01Hz Analog input: Maximum Frequency ×0.025% |
|
Frequency accuracy |
Digital input: Within 0.2% of the maximum output frequency Analog input: Set output frequency within 0.01% |
|
|
V/F control |
V/F curve (voltage frequency characteristics) |
The reference frequency can be set arbitrarily between 0.5~3000Hz, and the multi-point V/F curve can be set arbitrarily. Multiple fixed curves such as constant torque, reduced torque 1, reduced torque 2, and squared torque can also be selected |
|
Torque boost |
Automatically torque boost;Automatically determine the lifting torque based on the output current and combined with motor parameters manually torque boost: 0.0%~30.0% |
|
|
Automatic current and voltage limiting |
It can automatically detect the stator current and voltage of the motor during acceleration, deceleration, or stable operation, and suppress them within the allowable range based on a unique algorithm, minimizing the possibility of system fault tripping |
|
|
Senseless vector control |
Voltage frequency characteristics |
Automatically adjust the output voltage frequency ratio based on motor parameters and unique algorithms |
|
Torque characteristics |
Starting Torque: 150% rated torque at 3.0Hz (V/F control) 150% rated torque at 0.25Hz (sensorless vector control) Steady-state accuracy at operating speed: ≤±0.2% rated synchronous speed Speed Fluctuation: ≤±0.5% of rated synchronous speed Torque response: ≤20ms (sensorless vector control) |
|
|
Self-measurement of motor parameters |
Without any limitations, automatic parameter detection can be completed under both static and dynamic conditions of the motor to achieve the best control effect |
|
|
Current and voltage suppression |
Full process current closed-loop control, completely avoiding current surge, with complete overcurrent and overvoltage suppression function |
|
|
Control characteristics |
Under voltage suppression during operation |
Especially for users with low grid voltage and frequent fluctuations in grid voltage, even within the allowable voltage range, the system can maintain the longest possible operating time based on unique algorithms and residual energy allocation strategies |
|
Typical functions
|
Multi stage speed and swing frequency operation |
16 segments programmable multi speed control, with multiple operating modes to choose from. Swing frequency operation: preset frequency and center frequency adjustable, state memory and recovery after power failure |
|
PID Control RS485 Communication |
Built-in PID contro(Pre set frequency) Standard RS485 communication interface, support MODBUS-RTU communication protocol |
|
|
Input terminals |
Programmable digital inputs:Operation panel settings, RS485 interface settings, UP/DW terminal control, and multiple combination settings with analog inputs Programmable analog inputs: DC Voltage (0~10V), DC current (0~20mA). |
|
|
Output terminals |
Programmable digital outputs:1 channel Y terminal open-collector output, 1 channel DO high-speed pulse output (selectable as open-collector output), and two programmable relay outputs (TA, TB, TC) with up to 58 selectable functions Programmable analog outputs: Two analog signal outputs, with a flexible output range between 0~20mA or 0~10V, can achieve the output of physical quantities such as set frequency and output frequency |
|
|
Automatic voltage stabilization operation |
According to the needs, dynamic voltage regulation, static voltage regulation, and non voltage regulation can be selected to achieve the most stable operating effect |
|
|
Typical functions |
Acceleration and deceleration time setting |
0.0s~6500.0min continuously adjustable, S-type and linear mode optional |
|
Low noise operation |
The carrier frequency is continuously adjustable from 0.5KHz to 16.0KHz, minimizing motor noise to the greatest extent possible |
|
|
Speed tracking speed restart function |
Can achieve smooth restart and instantaneous stop restart functions of the motor during operation |
|
|
Counter |
One internal counter for easy system integration |
|
|
Running functions |
Upper and lower frequency settings, frequency jump operation, reverse operation restriction, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self recovery operation, etc |
|
|
Retardation |
Energy consumption braking |
The starting voltage, return voltage, and energy consumption braking rate of energy consumption braking can be continuously adjusted |
|
DC braking |
Starting frequency of DC braking during shutdown: 0.00~upper limit frequency Braking time: 0.0~100.0 seconds; Braking current: 0.0%~100.0% rated current |
|
|
Magnetic flux braking |
0~100 0: Invalid |
|
|
Display |
Running state |
Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback quantity, analog input and output, etc |
|
Alarm content |
Records eight operational parameters during three fault trips: output frequency, set frequency, output current, output voltage, DC voltage, module temperature, power-on time, and runtime |
|
|
Fault protection function |
Over current, over voltage, under voltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc |
|
|
Environ-ment |
Ambient temperature |
-10℃~40℃ (>40℃, output derated), without direct sunshine. |
|
Humidity |
5%~95%RH or less (non-condensing) |
|
|
Altitude |
≤1000M: output rated power, >1000M: output derated |
|
|
Environment |
Indoor (without direct sunlight, corrosion, flammable gases, oil mist, dust) |
|
|
Structure |
Protection level |
IP20 |
|
Cooling method |
Air cooling with fan control |
|
|
Installation method |
Wall mounted, cabinet mounted |
|
Warranty Agreement
1.The warranty period of this product is 18 months (subject to the barcode information of the machine body). During the warranty period, under the normal use of the user manual, our company is responsible for free repair of the product sales failure or damage.
2.During the warranty period, certain maintenance costs will be charged for damage caused by the following reasons:
The machine is damaged due to errors in use and unauthorized repair and transformation;
Machine damage caused by fire, flood, abnormal voltage, other premature disasters and secondary disasters;
Hardware damage caused by artificial fall and transportation after purchase;
Machine damage caused by not operating according to the user manual provided by our company;
Faults and damages caused by obstacles outside the machine (such as external equipment factors);
In case of product failure or damage, please fill in the contents of the “Product Warranty Card” correctly and in detail.
The charge of maintenance costs shall be subject to the latest adjusted “Maintenance Price List” of our company.
This warranty card will not be reissued under normal circumstances. Please be sure to keep this card and show it to the maintenance personnel during warranty.
In case of any problem during the service, please contact our agent or our company in time.
The Company reserves the right to interpret this agreement.
Manual Download
File size: 2.1MB
Packaging and Shipping
Factory
Customer Ratings
Customer Visit
Quote inquiry
Please provide your contact information and specify your requirements, and we’ll arrange for a specialist to get in touch with you!
3PH 380V±15% 1.5kw-200kw
Keywords:
Solar Pump model
Water Pump and Fans control model
Contact Us
Tel: +86 15806535521 (WeChat / WhatsApp)
Tel: +86 18363477011
E-Mail: suzy.su@sdlcgk.com
Address: Yanzhuang Industrial Zone, Gangcheng, Jinan, Shandong, China
More Products More +
LC700 Iron Shell VFD | Industrial Frequency Inverter Manufacturer & OEM Supplier
3PH 380V±15% 1.5kw-200kw
Medium Voltage VFD 690V 45–1200kW | LG300A Cabinet Frequency Inverter Manufacturer
3PH 690V±15% 45-1200KW
LC520 Elevator Dedicated Inverter - Open & Closed Loop Vector Control (7.5-18.5kW)
3PH 380V±15% 7.5-18.5KWLC520 | Vector Control Lift VFD for PMSM & Asynchronous Motor - Lcgk Vfd
Solar Water Pump VFD Inverter LC880P | MPPT AC Drive for Pumps & Fans
3PH 380V±15% 1.5-200KW
DC 350~900V